mbielowicz@xxxxx wrote: > targen -v -d4 -p1.88 -s200 -e4 -f0 Printer_calibration > printtarg -v -ii1 -R123 -pA4 Printer_calibration > in version 1.6.2 printtarg output: > .... > After optimisation, worst delta E = 66.372105 > Worst case direction distinction delta E = 61.873128 > In version 1.6.3 i have (the same commands): > .... > After optimisation, worst delta E = 21.000236 > Worst case direction distinction delta E = 21.914342 > Is such a difference normal? Hi, I don't seem to be able to reproduce this. I get the same numbers as 1.6.3 for releases back to 1.5.0 and before, given the same .ti1 file - ie. nothing seems to have changed with printtarg. Note that the effect of targen -p has been made more uniform (it wasn't being applied very consistently), so you will get slightly different .ti1 files out of 1.6.2 and 1.6.3, so maybe this is what is changing the contrast numbers. Graeme Gill.