Today I had 2 ME102s that I had to configure from Netgear.  I had 2
different disks, one with 1.3, the other with 2.0.  I installed the 1.3,
and configured one ME102 successfully.  I then tried to configure the
second ME102 with 1.3, but it came up with "The DFU driver has not been
loaded yet" error message.

What ultimately worked?  First, removing the 1.3 software.  I did it once
with the Add/Remove programs; another time, I did it with the uninstall
utility that the install created.  Second, and just as important, putting
the 2nd ME102 on a totally separate USB bus.  My PC has 2 USB ports in
front, and 2 in the rear.  The two groups are on 2 separate busses.  As
soon as I plugged the second ME102 into the rear USB group, instead of the
front one where I configured the first ME102, it was discovered correctly
by the PC and I could run the USB Manager utility to configure it.



Kevin McGuire
Integrity Computer Consultants
www.integritycomputerconsultants.com