[THIN] Re: Can't join farm

  • From: "Arthur Reyes" <artadmin@xxxxxxxxxxxxx>
  • To: <thin@xxxxxxxxxxxxx>
  • Date: Thu, 23 Dec 2004 10:46:15 -0600

Ok.  I found my problem.

Background:

I lost the password to my original DB Owner for my IMA Store, and I made it
*really* complex.  So I created another DB Owner with a password that was
similar.  However, my new DB Owner didn't have all the permission on my
database, even though I explicitly gave it the rights o DB Owner.  I had to
go into Users > Click my new user, highlight a permission, then click
permissions.  I checked every box that my previous DB Owner had checked, and
attempted the install again.

 

 

  _____  

From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx] On Behalf
Of Arthur Reyes
Sent: Wednesday, December 22, 2004 7:30 PM
To: thin@xxxxxxxxxxxxx
Subject: [THIN] Re: Can't join farm

 

Also.  This server is on the same subnet as my SQL server and Data Collector
for the Zone.  I know the port is open, because this server is on the same
port (it's the same server) as a server that existed in the farm previously.
Prior to reinstalling, I uninstalled Citrix to remove it from the farm.

 

  _____  

From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx] On Behalf
Of Arthur Reyes
Sent: Wednesday, December 22, 2004 7:19 PM
To: thin@xxxxxxxxxxxxx
Subject: [THIN] Can't join farm
Importance: High

 

Environment

W2Ksp4+Citrix XPe

SQL Backend

 

When I try to join a server to the farm, I get the error 

Cannot Get Property CTX_IMA_FARM_NAME.655CCDD2_63F2_4973_9D14_52C912BFB0E2

 

I've rebooted all my servers, and confirmed that I can recreate the LHC.

 

Curious.  I'm trying to install XPe on a slipstreamed W2Ksp4 cd.  I already
know that WI can't be installed on this type of machine, but does
slipstreaming sp4 also break the XPe install?

 

 

Other related posts: