If this filter is on the 130V line in the secondary of the SMPS then you main SMPS is running away! Check all filters in the primary of the SMPS ================================= Jeff Stielau Shoreline Electronics Repair 344 East Main Street Clinton,CT 06413 (860)399-1861 (860)664-3535 FAX jstielau@xxxxxxxx ================================= ----- Original Message ----- From: "Thomas Woodward" <thomas.woodward@xxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Monday, November 22, 2004 12:32 PM Subject: [TechAssist] mits vs50vf1 vented power supply cap > Hi > I have a Vs50vf1 with the 100Uf 200v cap > venting > I replaced it and the new one started to vent as soon as it cam up > I believe it is C-923 > > Any suggestions > > Thanks > Tom > Tri-valley repair > > > ----------------------------------------------------------------------------- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ > ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/