normally these three caps are all that is needed i have only replaced ic when it failed never had one come back for only replacing caps Robert tvservice@xxxxxxxxxxxxxxxxxxx H & H Electronics Inc ----- Original Message ----- From: "Wayne Vanaman" <Wayne@xxxxxxxxxxxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Monday, September 09, 2002 5:12 PM Subject: [TechAssist] Re: Toshiba CF3054J, TAC8950 still vert lin troublesafter C301 & C305 repl.] > > I don't believe the voltage rating has anything to do with discharge time. > That is a factor of capacity, esr, and possibly dialectric absorbtion > ("memory"). > > Check for ANY not-black caps, I believe that most of the Toshibas, but not > all, need three- c301, 305, 308, and sometimes the the 100uf or 220uf. > > Wayne Vanaman > Omega Electronics > 6904 W Fairfield Dr > Pensacola, Fl. 32506-3310 > > 850-456-5995 voice > 850-458-6369 fax > > Mailto:Wayne@xxxxxxxxxxxxxxxxxxxxx > WWW.PensacolaTVRepair.Com > > > ----- Original Message ----- > From: "Ed Gaidies" <teltek2@xxxxxxxxxxxx> > To: "TechAssist" <techassist@xxxxxxxxxxxxx> > Sent: Monday, September 09, 2002 4:05 PM > Subject: [TechAssist] Re: Toshiba CF3054J, TAC8950 still vert lin > troublesafter C301 & C305 repl.] > > > > > > Phil...... > > Always....always.......C308......220ufd/35volts. > > Due to the fact that these 2.2ufd/35 volts are timing > capacitors.....should > > never use higher than 50 volts.....discharge time is too great with a > > 250volt cap. I have never tried to go higher for that reason,,,although > you > > may be lucky. > > BTW...you may have to change the vertical O/P IC too. > > > > -Ed- > > Tel-Tek Electronics > > Midland, Ontario > > Canada. > > > > teltek2@xxxxxxxxxxxx > > teltek3@xxxxxxxxxxxx > > teltek@xxxxxxx > > > > "Quality will be remembered....long after Price is forgotten" > > > > > > > > Phil Bader The above is the reply to your message dated 9/9/02 2:33 PM > > > > > > > > > > > > > > 31" Toshiba TV CF3054J: Orig. symptom was very narrow vert. deflection > > > and fold over. > > > ESR'd C301 and C305, both 2.2/50V red electrolytics.Both very high, > > > almost infinate ESR. Replaced both with 2.2/250v @105 deg. (all I had). > > > Increased vert. heigth but still narrow by 4 inches top and bottom with > > > a top fold over. These two caps always do it. I measured the caps before > > > install and are exactly 2.2 mfd. What else am I overlooking here? > > > Phil Bader > > > > ------------------------------------------ > > To REMOVE your email address, click here: > > http://www.tech-assist.org/unsubb.html > > To CHANGE your email address, click here: > > http://www.techassist.net/forms/change.html > > ------------------------------------------ > > ***NEW*** Tips Added Instantly!!!*** > > Submit Repair Tips here: > > http://www.tech-assist.org/secure/tip/ > > > > ------------------------------------------ > To REMOVE your email address, click here: > http://www.tech-assist.org/unsubb.html > To CHANGE your email address, click here: > http://www.techassist.net/forms/change.html > ------------------------------------------ > ***NEW*** Tips Added Instantly!!!*** > Submit Repair Tips here: > http://www.tech-assist.org/secure/tip/ > ------------------------------------------ To REMOVE your email address, click here: http://www.tech-assist.org/unsubb.html To CHANGE your email address, click here: http://www.techassist.net/forms/change.html ------------------------------------------ ***NEW*** Tips Added Instantly!!!*** Submit Repair Tips here: http://www.tech-assist.org/secure/tip/