[TechAssist] Re: Tosh CE36G18 TAC 9708 relay clicks

  • From: Ralph Dorsey Atlas TV <Merlin-Wizard@xxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Thu, 26 Sep 2002 22:13:57 -0500

Jeff you can try changing the caps in the supply of course, and if that 
doesn't work then try and change the regulator then.  I've had problems 
with the vert and the audio being shorted and causing the set not to 
come on. Try un soldering those outputs and then see if set fires.

Lyles Tv wrote:

> I have 170vdc going to pin 1 of the str-z4151b  I don't have the schematic 
> for this set.  I suspect the strz, but cannot find the usual 2 pins shorted.  
> TIA
> And other voltages on the regulator are pulsing
> Jeff Farnsworth
> Lyles TV and Appliance
> 17 S Washington St
> Elkhorn, Wi.  53121
> ph    262-723-3477
> fax   262-723-3658
> tech@xxxxxxxxxxx
> 
> ------------------------------------------
> To REMOVE your email address, click here:
>   http://www.tech-assist.org/unsubb.html
> To CHANGE your email address, click here:
>   http://www.techassist.net/forms/change.html
> ------------------------------------------
> ***NEW*** Tips Added Instantly!!!***
> Submit Repair Tips here: 
> http://www.tech-assist.org/secure/tip/
> 
> 


-- 
Ralph Dorsey
Atlas TV Inc.
3945 s 76th St.
Milwaukee.Wi 53220
414-545-2303
Merlin-Wizard@xxxxxxx


------------------------------------------
To REMOVE your email address, click here: