The data and clock lines do stay busy all the time in this set. The new eeprom will not hold any settings until a diode is installed for 5 seconds to initialize the new eeprom. Instructions are on page 22 of the service manual AFTER the service menu alignment instructions. Confusing. ******************************************************************************************************************* Since 1972 Jim Myers Telrad Electronics Fort Wayne, Indiana Jim Myers wrote: > This started out as a dead set thanks to Mother Nature, a hand full of > parts were replaced to bring it back to life including the Micro and the > EEprom. The set works now but does not hold memory for customer > settings, channel settings, or service adjustments. The data and clock > pins at the EEprom stay busy all the time. Does anyone know if the Data > and Clock bus lines should go quiet as the RCA sets do or is this a sign > of a problem and may be why it won't store ant settings? > Thanks, > ******************************************************************************************************************* > Since 1972 > Jim Myers > Telrad Electronics > Fort Wayne, Indiana > > ----------------------------------------------------------------------------- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ > ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/