Applicable to the following chassis DX-1A used in many XBR 400/450 and KV32/36HS20 Wega sets. Symptom - Shutdown after 10 seconds with no picture displayed, sound OK. HV rises to normal. If G2 is increased a collapsed vertical deflection of reduced width is observed for a short time. Looks like bad vertical O/P. Solution - No Set 5V from regulator IC6007 due to a short measured across 5V output and ground from regulator.(located on main A board) Traced short to heat damaged FL3505 ( 1-233-512-21 - 37uH inductor) located on BC Pcb. This is a small sub daughter board located on the B board, connector CN3500, which then plugs into the main A board. Note - This was a little difficult to trace initially as a low ohm reading of less than 20 ohms is normal when measuring the set 5V rail to ground on the B board when removed from the set. Makes you look at the B board for the short. The BC board is easy to remove without dismantling everything if you know to check it first which I now do. Hope this saves someone some time in future on this relatively common chassis. This fault temps you into thinking you have a problem in the deflection stage rather than on the signal sub board. Glenn Larkman Audiotech 256 Nth Hwy 101 ENCINITAS CA 92024 760 944 9048 FAX 944 0345 mail to"mail@xxxxxxxxxxxxx" "www.audiotech.net" ***************************************************************************** Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/