Even with OEM from RCA I've had them fail after 2-3 hrs sometimes 24hrs later. I usually run at least a day before I return to customer. Did you change C14710 and R14704. These are two parts that come with OEM and recommended also to change when flyback fails............. -- ********************** Bill Grabowski Triangle Appliance 3813 Roosevelt Rd Kenosha WI 53142 262-694-6500 262-694-6523 fax bgrabowski@xxxxxxxxx ********************** Robinson Electronics wrote: >Has anyone seen these flybacks 237506 fail again (cracked blown winding), >after replaced 4 mo. ago? >Also replaced the hor. output Q14401. >May have replaced with a bad one, ordered another one to replace it. >Thanks for any help. David. > >Robinson Electronics >1075 Sweeten Creek Road #51 >Asheville, NC 28803-1757 >Ph./Fax. 828 274-3787 >Toll Free. 1-888 ROBELECT >www.robinsonelectronics.com >www.robelect.com >Mailto: RobinsonElectronics@xxxxxxxxxxx > >----------------------------------------------------------------------------- >This Email List is accessible to the general public through search engines. >Remove: http://www.tech-assist.org/remove.htm >Set Vacation mailto:ecartis@xxxxxxxxxxxxx?subject=set%20techassist%20vacation >Lost Password: http://www.tech-assist.org and select "Login Problems?". >Email Archives: //www.freelists.org/archives/techassist/ > > > > ----------------------------------------------------------------------------- This Email List is accessible to the general public through search engines. Remove: http://www.tech-assist.org/remove.htm Set Vacation mailto:ecartis@xxxxxxxxxxxxx?subject=set%20techassist%20vacation Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/