Don, On any CTC169 always Replace: Cr4118 P/N 164590 Ecg580 C4108 And C4102(2.2@100) and C4104 15@63 C4108 may be a 47uf or 39uf. I've seen the 47's fail...but not the 39's in C4108 Anyways....change those first 3 and you should be all set. Jeff Stielau Shoreline Electronics Repair 125 Beechtree Lane Westbrook,CT 06498 860-399-1861 Voice 860-664-3535 Fax jstielau@xxxxxxxx ----- Original Message ----- From: "Don & Sandra Montgomery" <wrf@xxxxxxxxxxxx> To: "Techassist" <techassist@xxxxxxxxxxxxx> Sent: Saturday, September 15, 2001 7:12 PM Subject: [TechAssist] RCA CTC169cc02 Dead > > Hi all this unit came in dead found Q4101 > shorted,have changed Q4101,CR4122,C4108 > and U4104. > Now standby voltage starts at 140v and rises > to 160v or more. > Any Ideas or help would be very appreciated > Thank so much Don > Hope you all can get over the membership deal > I don't feel I should ask for help BUT I will > try anyway ---HI AL > > > Help make your TechAssist online repair tips > database better! Submit your fixes here: > http://www.circuitwork.com/techassist/tip/#tips > To unsubscribe write to: > techassist-request@xxxxxxxxxxxxx > with unsubscribe in the subject line. > Help make your TechAssist online repair tips database better! Submit your fixes here: http://www.circuitwork.com/techassist/tip/#tips To unsubscribe write to: techassist-request@xxxxxxxxxxxxx with unsubscribe in the subject line.