Have you inspected the unit for coolant leakage?Remove the black plastic cover ( on top of the crts) and look for coolant at the bottom edge on crt mounting housing. Had on about 3 weeks ago had to replace the 7in gaskets and anodes and refill.HTH Country TV Ron Miller Inez, TX. 77968 ----- Original Message ----- From: "Bruce Tiedeman" <btied@xxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Tuesday, August 09, 2005 10:00 AM Subject: [TechAssist] RCA CTC169" Projection", Blue gun anode shorting to ground?? > Original problem CR4118 defective. Changing the diode allowed the set to > try > and start up but now has blue anode shorting to metal shield close to the > anode lead. > Removing the anode from the splitter allows the set to work, green and red > guns only. The filament for the blue gun is lit. The ground lead is > attached > to the blue crt. > I also tried changing the leads on the H.V splitter, but still have arcing > to ground problem on the blue gun. > My question is , does this mean the CRT has an internal short. If it is > the > gun , can one be had at a reasonable price even used. > thanks for your help, > Bruce > > B&T Electronics > 139 Margaret St > Sarnia Ontario > Canada > N7T 2Y3 > 519 344 1850 > > > ----------------------------------------------------------------------------- > This Email List is Public. Remove: http://www.tech-assist.org/remove.htm > Set Vacation > mailto:ecartis@xxxxxxxxxxxxx?subject=set%20techassist%20vacation > Lost Password: http://www.tech-assist.org and select "Login Problems?". > Email Archives: //www.freelists.org/archives/techassist/ > ----------------------------------------------------------------------------- This Email List is Public. Remove: http://www.tech-assist.org/remove.htm Set Vacation mailto:ecartis@xxxxxxxxxxxxx?subject=set%20techassist%20vacation Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/