[TechAssist] RCA CTC 211, model D61130. Auto convergence problem/Update!!

  • From: walter wood <wwood_38478@xxxxxxxxx>
  • To: Tech Assist <techassist@xxxxxxxxxxxxx>
  • Date: Thu, 19 Aug 2004 09:41:30 -0700 (PDT)


> So far, I've done this.
> I've removed the screen(the sensors are mounted
> in
> it).
> I've hooked a ohm meter across the two wires that
> go to each sensor(they seem to be in parallel.
> With the screen off the set I read 34K.
> When I shine a flashlight on any sensor I read
> 400
> to 900 ohms.
> I wondered why I read 500,000 ohms at the plug on
> the convergence end.
> So I covered the screen with a furniture pad(out
> of
> the set) and read 1.2 meg.
> Apparently all the sensors are working.
> I found some spider webs in the corners. I'll
> clean
> all that up, and reassemble, and let you know
> what
> happens.
> Walter



=====
Walter Wood                  
Future Tech Home Center        
2786 Hwy. 43 N.
Lawrenceburg Tn. 38464
931-829-3337
Fax 931-829-4044
mailto:wwood_38478@xxxxxxxxx

-----------------------------------------------------------------------------
Lost Password: