[TechAssist] Proscan PS31150 CTC169GL in shutdown/dead

  • From: "Peter oliver" <oliver_peter1@xxxxxxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Sat, 08 May 2004 21:46:57 +0000

Proscan
PS31150
CTC169GL

                   Set when plugged in will give a faint chip with a cycle 
of 8 or 9 smaller and dimishishing power supply start attempts (no attempt 
to start the rest of the set) B+ on C4141 peaks at about 189v for the 
instant it is there. The Cycling in the power supply sounds some what like a 
resonate decay ringing. Set before I got to it appears to have been 
extensivly reworked (time frame ?) ie eniter Micro circuit reworked (new 
shiny solder...) the power supply caps in the sw mode appear to have been 
replaced (they test ok out of circuit 2.2uf, 15uf, 47uf, 470uf) Tried 
subbing out diodes usch as CR4118, 4117, 4116. Did find a cap C4143 1000uf 
35v leaking electrolite but replacing had no effect (traces on underside of 
board show discoloration but still have continuity). C4401 tests ok (it is 
an orange drop in this set). I was thinking that the feedback might be 
sending incorect bias information to the regulator chip. (I have a spare 
chip but havent put in yet as supply appeared to be at least attempting to 
work, will be next step on monday. Ideas?

Peter Oliver
Tucson Radio TV