This set would come on with about 16KV and then shut down and relay would clatter about 3 times. I noticed that the HOT would get warm very Quickly. I removed the flyback and it rang perfect but I noticed that the casing around the flyback was warming up quite quickly after powering the set up two or three times. This goes to show that A flyback can ring perfect but be bad. replacement of the flyback p/n 312813821421 took care of the problem. John Conti,sTV Texas _________________________________________________________________ Don?t just search. Find. Check out the new MSN Search! http://search.msn.click-url.com/go/onm00200636ave/direct/01/ ----------------------------------------------------------------------------- This Email List is accessible to the general public through search engines. Remove: http://www.tech-assist.org/remove.htm Set Vacation mailto:ecartis@xxxxxxxxxxxxx?subject=set%20techassist%20vacation Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/