Does this set have D752 and D753? If so, check those. Bob Waterman, CET® Service Manager Gemini Computer, TV, & Security Alarm Systems, Inc. (508)695-7302 (508)695-7769 FAX geminitv@xxxxxxxxxxxxxxxx geminitv@xxxxxxx ----- Original Message ----- From: "don trippel" <dtrippel@xxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Thursday, May 09, 2002 2:27 AM Subject: [TechAssist] Hitachi model 26ax10bc ch m1clux-h (vertical jitter) > > Hello > > I am working on a Hitachi model 26ax10bc . The set has vertical > foldover and vertical jitter for about 20 minutes on startup. I have > checked all the usual caps in the circuit , in fact I have changed every > cap in the vertical circuit. Vcc is normal . After symptom has cleared > up I have tried freezing circuit with no response. I have wasted alot of > time on what is usually an easy fix, this one has me stumped. Any > advice would be appreciated. Thanks ! > > Don Trippel > Don's Electronics > Rosthern, Saskatchewan > Canada > > ------------------------------------------ > To REMOVE your email address, click here: > http://www.tech-assist.org/unsubb.html > ------------------------------------------ > ***NEW*** Tips Added Instantly!!!*** > Submit Repair Tips here: > http://www.tech-assist.org/secure/tip/ > ------------------------------------------ To REMOVE your email address, click here: http://www.tech-assist.org/unsubb.html ------------------------------------------ ***NEW*** Tips Added Instantly!!!*** Submit Repair Tips here: http://www.tech-assist.org/secure/tip/