the tube is not magnatized, there is no shadow mask, so degaussing wont help, did you replace both convergence ic's? I dont think the tube is the problem Ed Video pro-tech Mesa AZ ----- Original Message ----- From: <BOSS1996@xxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Thursday, September 16, 2004 10:33 AM Subject: [TechAssist] Hitachi 60EX38BA, convergence problem > Red conv. is misaligned in top right corner, pulled down in a "S" shape. > Replaced the conv. IC (stk4274) to no avail. Swapped the conv. connector to the > blue driver output to see if that particular corner would staighten out and no > good. Swapped yokes with no success either.I connected the blue tube to the red > conv. output and the "curve" was not there. > At this point I think perhaps the tube itself is magnetized, I have tried > degaussing the tube and the area around it but no help. > Am I on the right track here? If so, how can I get it demagnetized since my > normal degaussing ring does not seem to do it? > > > > Robert Cardoza > Picture Perfect Electronics > Pembroke Pines, Fla > 954-435-5868 > > > > -------------------------------------------------------------------------- --- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ > ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/