[TechAssist] Hitachi 27CX5B (ch# M3LXU) shuts down instantly,FIX, need service menu.]

  • From: Phil Bader <philbad@xxxxxxxxxx>
  • To: "techassist@xxxxxxxxxxxxx" <techassist@xxxxxxxxxxxxx>
  • Date: Thu, 27 Jun 2002 10:17:04 -0400



This model will shut down if no vertical is detected. Replaced vert.
output IC "I601, AN5521" and the B+ fuse device for the IC, "F601" #
2722382 (.75 Amp). Fixed... Now, I need to enter service menu to adjust
the grey scale. Need procedure and the parameters for R,G, and Blue
balance.