This is a follow-up on a post for a Panasonic PV840F VCR.... Unit came in with blown fuse. A serious lesson was learned. Under testing would blow fuse as soon as power cord was plugged in. Checked all components in power supply ... Q1= C4533 Regulator shorted....replaced with NTE2339 Q2 = D1458 also...replaced with NTE16006.. D1003,D1002,D1005,D1006, D1007, D1008all replaced. C1004 = 82uf/200v along with C1005 4.7uf/200v.....checked with CapWizard..and a ECG Cap Meter CX-920A..both showed them to be good. After replacing all components...fuse blew again....along with having to replace both Q1 & Q2....and D1008. Fix .... Removed both C1004 and C1005...using my Fluke Multi-meter ran resistance test.... C1004 =82uf read 2.4meg ohm C1005 4.7uf was weak on reading that would constantly increase.... Replaced both Cap's and Q1-Q2-D1008 Unit powered-up and had no other problems. Closing ..all I have to say is I will do a double test of Cap's from now on and not rely on any Cap tester alone. MONTE MONCRIEF BAKERSFIELD, CA. DOCVIDEO@xxxxxxxxxx Help make your TechAssist online repair tips database better! Submit your fixes here: http://www.circuitwork.com/techassist/tip/#tips To unsubscribe write to: techassist-request@xxxxxxxxxxxxx with unsubscribe in the subject line.