[TechAssist] Re: FIX! 2ND post[Fwd: IBM 2235-00N /Compaq 610,V50 (fcc# A3KM062, chassis CM1300) too wide,pin cush. no adjust.]

  • From: Phil Bader <philbad@xxxxxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Fri, 05 Oct 2001 18:57:22 -0400

It was the orange 3.3 mfd/63V bi-polor cap inside the flyback shield
area,hi ESR. lo capacitance.Replaced with a series/paralell combination
of 3.3 caps to make the proper value,since no BP cap available
here.Thanks all for help.

Phil Bader wrote:
> 
> -------- Original Message --------
> Subject: IBM 2235-00N /Compaq 610,V50 (fcc# A3KM062, chassis CM1300) too
> wide,pin cush. no adjust.
> Date: Fri, 05 Oct 2001 17:10:31 -0400
> From: Phil Bader <philbad@xxxxxxxxxx>
> Organization: Jan Phyl TV Inc. Winter Haven, Fl.  Estab. 1976
> To: "ELREPAIR-L@xxxxxxxxxxxxxxxxxxxx" <ELREPAIR-L@xxxxxxxxxxxxxxxxxxxx>
> 
> 15 inch monitor.I have checked all FET's, scan caps not shorted.It is
> too wide and bowed at sides and cannot adjust. No reaction. All other
> parameters can be adjusted (H.cent,V.pos,hgt. Brt,cont). Everything
> seems to run cool.On other units I suspect a shorted scan cap. This
> seems to be present on all scan mode freqs.This model is the same as a
> Philips chassis CM1300. Heeeeelp! ;-0 Phil
> Help make your TechAssist online repair tips
> database better!  Submit your fixes here:
> http://www.circuitwork.com/techassist/tip/#tips
> To unsubscribe write to:
> techassist-request@xxxxxxxxxxxxx
> with  unsubscribe  in the subject line.
Help make your TechAssist online repair tips 
database better!  Submit your fixes here: 
http://www.circuitwork.com/techassist/tip/#tips
To unsubscribe write to:
techassist-request@xxxxxxxxxxxxx 
with  unsubscribe  in the subject line.

Other related posts: