Winstips has a tip to check 12-V zener D124 and R442 (4.7 ohm, 2 wt).

Another tip says found glue under small ceramic disk near IC101 corroded
trace going to relay.

HTH,


Ken Smith
Gulf Technical Services
3034 Gulf Breeze Parkway
Gulf Breeze, FL  32563
850-934-8324 (Voice) 850-932-0819 (Fax)


On Sat, 6 Mar 2004 11:25:14 -0500 "Ed Gaidies" <teltek3@xxxxxxxxxxxx>
writes:
> Relay contact was burned away on this. Repaired it. Also resoldered 
> bad
> connection at R521 and R523. Still no Relay click. Shorting the Relay
> will bring set on.
> Ring a Bell for anyone?
> 
> -Ed-
> 
> Ed Gaidies
> Tel-Tek Electronics.
> Ontario-Canada
> 
> teltek3@xxxxxxxxxxxx 
> 
> 
> 
>
-------------------------------------------------------------------------
----
> Lost Password:
> http://www.tech-assist.org  and select "Login Problems?".