[TechAssist] Emerson TC1351 FIXED

  • From: "al m" <ampm@xxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Fri, 7 Nov 2003 12:50:38 -0500

this unit had no power. Replacing R453 1K 7W restored power,C402 and C668
were both open on ESR meter. These are all in the 5V standby section of the
power supply. Thanks to Ed and Jeff for the help.
Al Marquardt