[TechAssist] Re: CTC185 Blows H/O and Volt.reg

  • From: "jonas miglinas" <miglinasj@xxxxxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Fri, 17 Feb 2006 19:19:29 -0600

I've had a few come back to me the past year, ended up throwing out(even =
if it checks good) C4153, 33uf/200v.
Check if CR4117 is leaky.


Jonas Miglinas
Miglinas TV Chicago
----- Original Message -----=20
From: "STERLING PASHER" <spasher@xxxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Friday, February 17, 2006 1:50 PM
Subject: [TechAssist] CTC185 Blows H/O and Volt.reg


> I had a CTC185 come in shop, H/O and Volt Reg. were blown. I checked
> everything else (ESR'd caps ,rang F/B and yoke) did the S to D short =
with 85
> Volt on variac and all checked OK. After replacing The H/O and Volt. =
Reg ran
> set for five hours in shop. Brought to customer and it lasted about 3 =
hours
> and it blew everything again. Has anyone had this experience  with the =
185
> and any fix for it. Hate those returns.
>=20
> Buck Pasher
> Buck's TV
> Gander Newfoundland
> Canada
> 709-256-7738 (Fax & Phone)
>=20
>=20
>=20
>=20
> =
-------------------------------------------------------------------------=
----
> This Email List is accessible to the general public through search =
engines. Remove: http://www.tech-assist.org/remove.htm
> Set Vacation =
mailto:ecartis@xxxxxxxxxxxxx?subject=3Dset%20techassist%20vacation
> Lost Password: http://www.tech-assist.org  and select "Login =
Problems?".
> Email Archives: //www.freelists.org/archives/techassist/
> 
-----------------------------------------------------------------------------
This Email List is accessible to the general public through search engines. 
Remove: http://www.tech-assist.org/remove.htm
Set Vacation mailto:ecartis@xxxxxxxxxxxxx?subject=set%20techassist%20vacation
Lost Password: http://www.tech-assist.org  and select "Login Problems?".
Email Archives: //www.freelists.org/archives/techassist/

Other related posts: