[TechAssist] Bear of a Sanyo DS35590 HOT shorts at plug in

  • From: "Terry J Hutchison" <sony1@xxxxxxxx>
  • To: "techassist" <techassist@xxxxxxxxxxxxx>
  • Date: Tue, 18 Jan 2005 22:22:38 -0500

Set came in dead(lightning) I have done this repair a couple of times and 
posted it to this forum, my personal data base crashed and I have had to start 
over.  I found the usual Q601 short, Q604 short, also found D603 short, Q635 
open, the HOT Q403 was good.  After replacing these along with the coupler I 
pluged in set to check secondary voltages, oopps. At plug in relay throws and 
HOT instantly shorts, all components replaced in primary still check good.  I 
began to do cold checks on the secondary and found the following diodes with 
low ohmage readings in circuit D489(in other sets this was D1901 I think), D311 
and D312 these all check normal when removed from chasis in chasis reading 
between 150 to 250 ohms.
   I checked all the diodes in the area of the IHVT and they check good in 
circuit.  Sure could use a helping hand here.   Thanks Terry

Terry J Hutchison
T&G Television Repair
Kingsland, Ga.
sony1@xxxxxxxx