Just ran across this in WinsTips, different model, 2248R01 but also a Philips chassis and same symptom, excessive width and pincushion problem. Bad solder at L405 not sending signal to pincushion correction circuit. Give it a look. Jim Myers jr.myers@xxxxxxxxxxx ----- Original Message ----- From: "Phil Bader" <philbad@xxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Friday, October 05, 2001 4:12 PM Subject: [TechAssist] 2ND post[Fwd: IBM 2235-00N /Compaq 610,V50 (fcc# A3KM062, chassis CM1300) too wide,pin cush. no adjust.] > > > > -------- Original Message -------- > Subject: IBM 2235-00N /Compaq 610,V50 (fcc# A3KM062, chassis CM1300) too > wide,pin cush. no adjust. > Date: Fri, 05 Oct 2001 17:10:31 -0400 > From: Phil Bader <philbad@xxxxxxxxxx> > Organization: Jan Phyl TV Inc. Winter Haven, Fl. Estab. 1976 > To: "ELREPAIR-L@xxxxxxxxxxxxxxxxxxxx" <ELREPAIR-L@xxxxxxxxxxxxxxxxxxxx> > > 15 inch monitor.I have checked all FET's, scan caps not shorted.It is > too wide and bowed at sides and cannot adjust. No reaction. All other > parameters can be adjusted (H.cent,V.pos,hgt. Brt,cont). Everything > seems to run cool.On other units I suspect a shorted scan cap. This > seems to be present on all scan mode freqs.This model is the same as a > Philips chassis CM1300. Heeeeelp! ;-0 Phil > Help make your TechAssist online repair tips > database better! Submit your fixes here: > http://www.circuitwork.com/techassist/tip/#tips > To unsubscribe write to: > techassist-request@xxxxxxxxxxxxx > with unsubscribe in the subject line. Help make your TechAssist online repair tips database better! Submit your fixes here: http://www.circuitwork.com/techassist/tip/#tips To unsubscribe write to: techassist-request@xxxxxxxxxxxxx with unsubscribe in the subject line.