Hello all, From reply, seems one VT table account for only one of Pullup and Pulldown transistor terminated to one of rails. And simulator tools will merge affections. For a falling waveform of VT table terminated to VCC, only account for Pulldown transistor turning on. No Pullup transistor affection included in this table, althrough there may have current flow from VCC through Pullup andPulldown transistors to ground. The simulation tool will calculate this part of current from other VT tables(is it the falling wavefrom of VT table that terminated to ground? the timing relativeship between them decide how tocaculate). Am I right? thanks! zhiwei ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List technical documents are available at: http://www.si-list.net List archives are viewable at: //www.freelists.org/archives/si-list Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu