Hi Guys, I have a 32-Bit processor interfaced to an ULPI tranceiver. The bus is at 60Mhz. One of the control signal from the processor (STP) is more in length by 300mils w.r.t the clock. The total length of the line is 1700mils. No termination. Stripline routing. If i set the STP pin at slow slew rate (Processor pin configuration), then my USB communication fails. The CRC is detected wrongly (Data is correct. ) But if i set the STP pin at fast slew rate, it works fine. Question 1. Is 300mils increase a major factor? Set up time requirement is 4.5ns. I could not get any info on the rise time. Regards Balaji S ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List technical documents are available at: http://www.si-list.net List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu