Re: which patch wizard tool is more accurate

  • From: Subodh Deshpande <deshpande.subodh@xxxxxxxxx>
  • To: John Piwowar <jpiwowar@xxxxxxxxx>
  • Date: Fri, 6 Aug 2010 17:47:35 +0530

Thanks John and Niall,

yes agreed both serves different purposes, patchwizard can be used
for verification of patch plan.

I was confused because 4229931 is shown as AD.I.2 in patchsets.sh reports
 which is not, its just post AD.I.1, the abstract of this patch is Post
AD.I..1 Consolidated 07/27/05
and 4337683 is AD.I.2 the abstract is also AD.I.2.

in one of my patch requirement I require AD.I.2. Patchset report shows
applied where patchwizard shows it is required. So I will have to apply
4337683 now..


Thanks!
Subodh




On 6 August 2010 12:02, John Piwowar <jpiwowar@xxxxxxxxx> wrote:

> Subodh,
>
> This is not really a question of accuracy.  All of these tools serve
> different purposes.  The patchsets.sh script simply tells you what family
> packs and minipacks are installed on your system, and whether there are
> updated versions.  You didn't mention how you are using the OAM patch
> wizard, so those results are less clear.  If you were using it to evaluate a
> patch and determine its prerequisites, then the patch wizard is probably
> just doing its job: telling you that patch 4229931 (AD.I.2) is a
> prerequisite for another patch.  The OAM patch wizard won't necessarily
> ignore a prerequisite if it's already installed.
>
>  Regards,
>
> John P.
>
> On Thu, Aug 5, 2010 at 8:04 AM, Subodh Deshpande <
> deshpande.subodh@xxxxxxxxx> wrote:
>
>> Hi List,
>>
>> Which patch compareason/analysing tool is more accurate
>>
>> patchsets.sh
>> patch wizard available in oracle apps manager or
>> CCR linked with metalink support
>>
>> I am asking this because, I am confused with follwoing
>>
>> patchsets.sh shows
>>
>>
>> SHARED INSTALL PRODUCTS
>>
>> Product Baseline Version Running Version Latest Available,Status
>>
>> ------- ----------------- --------------- -----------------------
>>
>> ad 11i.AD.I.1(4038964) 11i.AD.I.2(4229931) 11i.AD.I.6(6502082),
>> Rel-By_Metal
>>
>> it means my running vesion is AD.I.2 and is also shown in adadmin, but
>> patchwizard shows me that I will have to apply 4337683 which is ad patch.
>>
>>
>>
>> Please help..
>>
>>
>>
>> Thanks!
>>
>> Subdoh
>>
>>
>> --
>> ==============================
>> DO NOT FORGET TO SMILE TODAY
>> ==============================
>>
>
>


-- 
==============================