Many very good UBM systems out there. Look at (demo) all frequencies available and then choose a system that meets the needs of all specialties you have to serve. Also if you want to repair your I-cubed, or sell it to me for spare parts for my service dept, please contact me. Cynthia Kendall BMET, CDOS, ROUB Mobile Eye Ultrasound (916) 955-8288 Echography@xxxxxxxxxxx Sent from my iPhone > On Aug 20, 2014, at 10:12 PM, "FreeLists Mailing List Manager" > <ecartis@xxxxxxxxxxxxx> wrote: > > optimal Digest Wed, 20 Aug 2014 Volume: 05 Issue: 130 > > In This Issue: > [optimal] Need advise on B-scan ultrasound devise > [optimal] UBM information > [optimal] Re: UBM information > [optimal] Re: UBM information > [optimal] Re: Need advise on B-scan ultrasound devise > [optimal] Re: Need advise on B-scan ultrasound devise > [optimal] Is anyone offering support for the WinStation from > [optimal] Re: Is anyone offering support for the WinStation > > ---------------------------------------------------------------------- > > Date: Wed, 20 Aug 2014 15:00:03 -0400 > Subject: [optimal] Need advise on B-scan ultrasound devise > From: Raymond Mok <raywmok@xxxxxxxxx> > > Hi folks, > Our 15+ years old iCube B scan ultrasound is acting strange recently. It > will freeze up in the middle of a test lately and needs to restart and also > having problem uploading into the server. > I wonder if someone can suggest an ultrasound unit that can also perform > UBM (high resolution ultrasound as the iCube). Our manager would like to > have a few options so we can compare the prices. I have tried to do > some research online but with very few to choose from. > Thanks so much for your help and feed back. > > Ray Mok, CRA, COMT > Dartmouth-Hitchcock Medical Center-Ophthalmology > One Medical Center Dr. > Lebanon, NH 03756 > > > > ------------------------------ > > From: CPMC Ophthalmic Diagnostic Center <cpmceyelab@xxxxxxxxxxxxxxxx> > Date: Wed, 20 Aug 2014 12:03:42 -0700 > Subject: [optimal] UBM information > > N«z+'¢Ö¥j¸™ªäz×è@LþØn³ûayÈh‰Ç¬j·¥ŠhyÔáyšž×¥ºxŠËÞ¯'âïÚ²+-…àrëh™àh¶Z½çâêk¡·¬"ßÿþÆ¥•¦èºÛazšèmïÿ¶ > zw«jبž‡í…è¦jÿ¶«zÊ%ºØ¨œ > ݶŸºw-Š‰Ú–+r¡ûazÊ·«{ÿÿüˆ^j»azw°J‰è™çnž+b²«¢µè¦¦·¬²+Þý8^Š¸¦jª¹©b·(¬±¨ý¼žÆ—«¶Ïí¡·¢™èµÈpŠØfj¹v)©®‹Þ™éí²‰é®†Þjwb™¨ë(–ëb¢È‹¥uÈ^rKa¢Ç¢›a眢{^׫³ÿÃzxœxÚŠv§r&¥Š{^ë-"©¥éí¢ë¶€T„Žºx›+•ÿߢºÞjÊ'°†¦…ªiÊÚŠÇ.²Ê~X§{ðÞž'éâqàZ®ÉÞ²ÏÂDÂ8ÄÿDåü > ÎKñN=#©†ØZ–hœ& ž‹-‰Àžž×«óêZ®ÙžžÚ:˜m…©f¢Z > ËmtÑg›²×«JÚÞzÔ®Š×¶×dšœZÚȬr€€÷uçþ5çþ´Óýýß±@_þ5çþ´Óþ¹ëqk¢oè¦Ø¦j_Û¢éÜ{÷ëyéb²Ûÿ¢¸ÿ™¨¥¶è¦Ø¦j_Û¢éÜ{÷ëyéb²Ûÿ¢¸ÿ:p^…©_9ôZÊj'tÊ$Iéíýgëk/Àº¬·mÿÛMx×oôÐó£ú)¶)š—÷ëyéb²Ûÿ¢¸¹¸Þrßÿ¢›b™©ÿ5çiÛâ±ê'ûj{¥¶¶¬¢éÝuëâ±áâ~‰d³ó®¯^~É櫲‰]ˆ+›xj{¥¶¶¬¢éÝŠÆœ¶)à²ÚÚž«yǧ¶\ÿ"Ü"–WëyìÞº˜§¶¦‰×ez‡Úµë-•«^—&§vwžvËhë-j»ZÖ¥²ˆZ¾)঺•é®¦Zv)àŠ{h¶¬z»Þ¯ò0¢w^®'ì¢g¨çžË > ë-j{¥¶¶¬¢éݺx¶q©Ú–Ê)z·è®e3øb‚Þ²‰n¶*'º[kjÊ.Ö¬¶¢ > æÞÿó®®f§j«Â‹¥vX¤zÚ!j÷š}ì(¦Ø¨žË(ÁçÊ&¥ªÞ¶©®'³ò!j÷®'¶‡h²‰žëj·!¢ybæî·†÷«É÷°¶‡!¢‹~º&ý8ZžK,¢kœ…ú+Ê‹«…éijw_yç[iÉÿE¬Œ¢OÂDÂ8ÄÃj»f¢ëaüxr(rCv'”'§µêÿ:˜m…©f¢Z > ÈéÞ1çbq©Bz{^¬:ÿ-æÚž‰ÿ4}7 > > ------------------------------ > > Date: Wed, 20 Aug 2014 15:13:11 -0400 > Subject: [optimal] Re: UBM information > From: Raymond Mok <raywmok@xxxxxxxxx> > > Thanks so much for the info Denice. > Ray > > Ray Mok, CRA, COMT > > Dartmouth-Hitchcock Medical Center-Ophthalmology > > One Medical Center Dr. > > Lebanon, NH 03756 > > > On Wed, Aug 20, 2014 at 3:03 PM, CPMC Ophthalmic Diagnostic Center < > cpmceyelab@xxxxxxxxxxxxxxxx> wrote: > >> There is not a large market for UBM- thus, the choices are limited >> >> >> >> The Quantel unit is very fine, as is the Accutome >> >> Both have fine probes >> >> It’s all about the probe!, the generation of the image, the resolution >> >> >> >> And the functionality of the software…. >> >> >> >> I hear the new Sonomed unit is quite impressive. Their image quality is >> said, by experts , to be top notch with marked improvements on probe and >> image resolution. >> >> >> >> I would check those top three contenders.. >> >> >> >> >> >> Denice >> >> No financial interest >> >> I happen to use the AVISO unit myself, for reasons I am happy to discuss >> off line. >> >> >> >> Denice >> >> >> >> >> >> *Denice Barsness, CRA, COMT, ROUB, CDOS, FOPS* >> >> *Ophthalmic Diagnostic Center* >> >> *CPMC Department of Ophthalmology* >> >> *2100 Webster Street Suite 212* >> >> *San Francisco CA 94115* >> >> *(415) 600-3937 <%28415%29%20600-3937> FAX (415) 600-6563 >> <%28415%29%20600-6563>* >> >> >> >> *From:* optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx] >> *On Behalf Of *Raymond Mok >> *Sent:* Wednesday, August 20, 2014 12:00 PM >> *To:* optimal@xxxxxxxxxxxxx >> *Subject:* [optimal] Need advise on B-scan ultrasound devise >> >> >> >> Hi folks, >> >> >> >> Our 15+ years old iCube B scan ultrasound is acting strange recently. It >> will freeze up in the middle of a test lately and needs to restart and also >> having problem uploading into the server. >> >> I wonder if someone can suggest an ultrasound unit that can also perform >> UBM (high resolution ultrasound as the iCube). Our manager would like to >> have a few options so we can compare the prices. I have tried to do >> some research online but with very few to choose from. >> >> Thanks so much for your help and feed back. >> >> >> >> Ray Mok, CRA, COMT >> >> Dartmouth-Hitchcock Medical Center-Ophthalmology >> >> One Medical Center Dr. >> >> Lebanon, NH 03756 > > > ------------------------------ > > Date: Wed, 20 Aug 2014 15:24:53 -0400 > Subject: [optimal] Re: UBM information > From: Martin Mayers <martin.mayers@xxxxxxxxx> > > we demo'd the Sonomed yesterday - I concur > > On Wed, Aug 20, 2014 at 3:03 PM, CPMC Ophthalmic Diagnostic Center < > cpmceyelab@xxxxxxxxxxxxxxxx> wrote: > >> There is not a large market for UBM- thus, the choices are limited >> >> >> >> The Quantel unit is very fine, as is the Accutome >> >> Both have fine probes >> >> It’s all about the probe!, the generation of the image, the resolution >> >> >> >> And the functionality of the software…. >> >> >> >> I hear the new Sonomed unit is quite impressive. Their image quality is >> said, by experts , to be top notch with marked improvements on probe and >> image resolution. >> >> >> >> I would check those top three contenders.. >> >> >> >> >> >> Denice >> >> No financial interest >> >> I happen to use the AVISO unit myself, for reasons I am happy to discuss >> off line. >> >> >> >> Denice >> >> >> >> >> >> *Denice Barsness, CRA, COMT, ROUB, CDOS, FOPS* >> >> *Ophthalmic Diagnostic Center* >> >> *CPMC Department of Ophthalmology* >> >> *2100 Webster Street Suite 212* >> >> *San Francisco CA 94115* >> >> *(415) 600-3937 <%28415%29%20600-3937> FAX (415) 600-6563 >> <%28415%29%20600-6563>* >> >> >> >> *From:* optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx] >> *On Behalf Of *Raymond Mok >> *Sent:* Wednesday, August 20, 2014 12:00 PM >> *To:* optimal@xxxxxxxxxxxxx >> *Subject:* [optimal] Need advise on B-scan ultrasound devise >> >> >> >> Hi folks, >> >> >> >> Our 15+ years old iCube B scan ultrasound is acting strange recently. It >> will freeze up in the middle of a test lately and needs to restart and also >> having problem uploading into the server. >> >> I wonder if someone can suggest an ultrasound unit that can also perform >> UBM (high resolution ultrasound as the iCube). Our manager would like to >> have a few options so we can compare the prices. I have tried to do >> some research online but with very few to choose from. >> >> Thanks so much for your help and feed back. >> >> >> >> Ray Mok, CRA, COMT >> >> Dartmouth-Hitchcock Medical Center-Ophthalmology >> >> One Medical Center Dr. >> >> Lebanon, NH 03756 > > > ------------------------------ > > Subject: [optimal] Re: Need advise on B-scan ultrasound devise > From: "Ellen Redenbo" <ellen.redenbo@xxxxxxxxxxxxxxxxx> > Date: Wed, 20 Aug 2014 13:10:55 -0700 > > Content-Type: text/plain; > charset=us-ascii > Content-Transfer-Encoding: 7bit > Quantel makes a 20MHz posterior B probe that is superb for looking at fine > retinal tears on their Aviso machine. (Which also has UBM) > > Ellen Redenbo, CDOS, CRA, ROUB, Supervisor > Ophthalmic Imaging Center > UC Davis Eye Center > 4860 Y Street, Suite 2400 > Sacramento, CA 95817-2307 > Phone (916) 734-1094 > Page (916) 816-1632 > Fax (916) 734-6992 > > > > > > From: Raymond Mok <raywmok@xxxxxxxxx> > To: optimal@xxxxxxxxxxxxx > Date: 08/20/2014 12:01 PM > Subject: [optimal] Need advise on B-scan ultrasound devise > Sent by: optimal-bounce@xxxxxxxxxxxxx > > > > Hi folks, > > Our 15+ years old iCube B scan ultrasound is acting strange recently. It > will freeze up in the middle of a test lately and needs to restart and > also having problem uploading into the server. > I wonder if someone can suggest an ultrasound unit that can also perform > UBM (high resolution ultrasound as the iCube). Our manager would like to > have a few options so we can compare the prices. I have tried to do > some research online but with very few to choose from. > Thanks so much for your help and feed back. > > Ray Mok, CRA, COMT > Dartmouth-Hitchcock Medical Center-Ophthalmology > One Medical Center Dr. > Lebanon, NH 03756 > > > > > > > ------------------------------ > > Date: Wed, 20 Aug 2014 16:24:21 -0400 > Subject: [optimal] Re: Need advise on B-scan ultrasound devise > From: Raymond Mok <raywmok@xxxxxxxxx> > > Thanks for the info Ellen. I'll look into that. > Ray Mok > > Ray Mok, CRA, COMT > > Dartmouth-Hitchcock Medical Center-Ophthalmology > > One Medical Center Dr. > > Lebanon, NH 03756 > > > On Wed, Aug 20, 2014 at 4:10 PM, Ellen Redenbo < > ellen.redenbo@xxxxxxxxxxxxxxxxx> wrote: > >> Quantel makes a 20MHz posterior B probe that is superb for looking at fine >> retinal tears on their Aviso machine. (Which also has UBM) >> >> Ellen Redenbo, CDOS, CRA, ROUB, Supervisor >> Ophthalmic Imaging Center >> UC Davis Eye Center >> 4860 Y Street, Suite 2400 >> Sacramento, CA 95817-2307 >> Phone (916) 734-1094 >> Page (916) 816-1632 >> Fax (916) 734-6992 >> >> >> >> >> >> From: Raymond Mok <raywmok@xxxxxxxxx> >> To: optimal@xxxxxxxxxxxxx >> Date: 08/20/2014 12:01 PM >> Subject: [optimal] Need advise on B-scan ultrasound devise >> Sent by: optimal-bounce@xxxxxxxxxxxxx >> ------------------------------ >> >> >> >> Hi folks, >> >> Our 15+ years old iCube B scan ultrasound is acting strange recently. It >> will freeze up in the middle of a test lately and needs to restart and also >> having problem uploading into the server. >> I wonder if someone can suggest an ultrasound unit that can also perform >> UBM (high resolution ultrasound as the iCube). Our manager would like to >> have a few options so we can compare the prices. I have tried to do >> some research online but with very few to choose from. >> Thanks so much for your help and feed back. >> >> Ray Mok, CRA, COMT >> Dartmouth-Hitchcock Medical Center-Ophthalmology >> One Medical Center Dr. >> Lebanon, NH 03756 > > > > > ------------------------------ > > From: "Chuck" <cetienne@xxxxxxxxxx> > Subject: [optimal] Is anyone offering support for the WinStation from OIS? > Date: Wed, 20 Aug 2014 18:36:34 -0400 > > Content-Type: text/plain; > charset="us-ascii" > Content-Transfer-Encoding: 7bit > > > Is any company offering support for the WinStation system? Merge and I are > not working out on all fronts. > > > > Chuck Etienne, CRA > > etiennec@xxxxxxxxxxxxxxxx > > (937)626-4927 cell > > > > > > > > ------------------------------ > > From: Peter Hay <peterhay@xxxxxxx> > Subject: [optimal] Re: Is anyone offering support for the WinStation from OIS? > Date: Wed, 20 Aug 2014 19:05:32 -0400 > > Chuck- > Recent contact (this month) with support has been extremely frustrating. I > don't think Merge wants OIS to survive. They appear to not give much > resources to the support team. I wish they would sell the division to any > party who was interested in bring back the old OIS superb product and team. > > Peter Hay > > Sent from my iPad > >> On Aug 20, 2014, at 6:36 PM, Chuck <cetienne@xxxxxxxxxx> wrote: >> >> <image001.jpg> >> Is any company offering support for the WinStation system? Merge and I are >> not working out on all fronts. >> >> >> >> Chuck Etienne, CRA >> >> etiennec@xxxxxxxxxxxxxxxx >> >> (937)626-4927 cell > > > ------------------------------ > > End of optimal Digest V5 #130 > ***************************** >