[optimal] Re: OIS capture station issues...

  • From: sandor ferenczy <sandorferenczy@xxxxxxxxx>
  • To: optimal@xxxxxxxxxxxxx
  • Date: Tue, 14 Aug 2012 12:57:07 -0400

thats what i have been looking for.

when someone inadvertently restarts the capture1 machine, the others can
continue to capture, so i know it *can* do it, just need to figure out how
to force the issue.


On Tue, Aug 14, 2012 at 12:47 PM, James Strong <jamesdstrong@xxxxxxxxx>wrote:

> Can you open the .ini file and identify where the main DB is defined and
> modify it to point to capture 2?  Probably not that simple...but it doesn't
> hurt to look.
> After saving a copy of the original .ini, of course.
>
> j-
>
> On Tue, Aug 14, 2012 at 12:26 PM, sandor ferenczy <
> sandorferenczy@xxxxxxxxx> wrote:
>
>> So, question for the collective...
>>
>> If the main OIS capture station (capture1 we'll call it) dies (CPU power
>> supply or motherboard) is there any way to quickly get the other capture
>> stations (capture2, capture3, etc) up and running?
>>
>> as it sits now, capture1 is dead, and capture2 and capture3 will not
>> start the Winstation application, as they cannot connect to the database
>> (which resides on capture1)
>>
>> any quick help is much appreciated!
>>
>> -sandor
>>
>
>

Other related posts: