[Linuxtrent] Re: broadcom netxtreme gigabit ethernet

  • From: Flavio Visentin <visentin@xxxxxxxxxx>
  • To: linuxtrent@xxxxxxxxxxxxx
  • Date: 16 Jul 2003 09:53:02 +0200

> Installing module bcm5700. If the device isn't there, or isn't configured 
> correc                              tly, this could cause your system to 
> pause for up to a minute.
> 
> /lib/modules/2.4.18-bf2.4/kernel/drivers/net/bcm5700.o: init_module: No such 
> dev                              ice
> Hint: insmod errors can be caused by incorrect module parameters, including 
> inva                              lid IO or IRQ parameters
> /lib/modules/2.4.18-bf2.4/kernel/drivers/net/bcm5700.o: insmod 
> /lib/modules/2.4.                              
> 18-bf2.4/kernel/drivers/net/bcm5700.o failed
> /lib/modules/2.4.18-bf2.4/kernel/drivers/net/bcm5700.o: insmod bcm5700 failed
> 

A me è capitato su alcuni server DELL che la scheda funzionasse con il
modulo tr3.o quindi magari prova anche quelli (dovrebbero essere
pressoché equivalenti); in ogni caso il modulo bcm5700 è parte ufficiale
del kernel, sicuramente dalla 2.4.20 in poi.

Se la scheda (integrata??) è MOLTO recente può essere che ti sia
sufficiente aggiungerne le caratteristiche al file
/lib/modules/modules.pcimap (I valori da inserire li ottieni con il
comando lspci). A volte capita che il vendor cambi il codice e che
quindi il kernel non riesca a riconoscere correttamente il modulo da
utilizzare riportandoti l'errore evidenziato.
Flavio Visentin

-- 
Per iscriversi  (o disiscriversi), basta spedire un  messaggio con OGGETTO
"subscribe" (o "unsubscribe") a mailto:linuxtrent-request@xxxxxxxxxxxxx


Other related posts: