[ibis-editorial] Re: clock_times conflict?

  • From: "Walter Katz" <wkatz@xxxxxxxxxx>
  • To: <ibis-editorial@xxxxxxxxxxxxx>
  • Date: Fri, 18 May 2012 08:36:25 -0400 (EDT)

MM, Arpad,

 

If an Rx AMI_Getwave function that returns clock_times is operating
correctly, it should return (after ignore_bits), one clock time every ~
1UI.  Two bad things can happen:

 

First the CDR can lose lock, and the reported clock times are at the
"wrong frequency" causing them to drift through the recovered eye. The EDA
tool will simply report a terrible BER, as it should. 

 

The second is that the Rx AMI_Getwave skips clock times. I would consider
this a flawed DLL, since clocks in CDRs do run continuously, the CDR just
adjusts the phase of the clock. The EDA tool should be able to detect this
flawed DLL since adjacent clock times should be separated by 1UI +/-
Jitter. Jitter should be < UI/2, so this is an easy sanity check tat an
EDA tool should make.

 

Walter

 

From: ibis-editorial-bounce@xxxxxxxxxxxxx
[mailto:ibis-editorial-bounce@xxxxxxxxxxxxx] On Behalf Of Muranyi, Arpad
Sent: Thursday, May 17, 2012 9:50 PM
To: ibis-editorial@xxxxxxxxxxxxx
Subject: [ibis-editorial] Re: clock_times conflict?

 

Mike,

 

A -1 marks the end of the series of clock time values, but

-1 itself is really not a clock time value.  Also, the tool

is not required to continue reading the clock times vector

after it found a -1.

 

So for an Rx that doesn't return clock times it is enough to

have a single -1 at the beginning of this vector, but the 

model can also fill the entire vector with -1's if it has

nothing else to do.  It doesn't matter, because the tool is

not required to read past the first -1.

 

An interesting question which I am not sure if it is explained

clearly is:  what happens if the CDR goes out of lock and then

regains its normal operation.  What is it supposed to do while

it is out of lock?  It can't put -1 into the vector because

that's the end of the data.  It can't put 0 there either

because that will make the data non monotonic.  It can't keep

repeating the last number either because the numbers supposed

to get bigger.  So what can it do?  Does this mean that going

in/out of lock can't happen?

 

Thanks,

 

Arpad

================================================================

From: ibis-editorial-bounce@xxxxxxxxxxxxx
[mailto:ibis-editorial-bounce@xxxxxxxxxxxxx] On Behalf Of Mirmak, Michael
Sent: Thursday, May 17, 2012 7:34 PM
To: ibis-editorial@xxxxxxxxxxxxx
Subject: [ibis-editorial] clock_times conflict?

 

In the current draft, clock_times (part of AMI_GetWave) contains as part
of its definition, the following text:

 

Any non-strict monotonic behavior of clock times (including two identical
values) should be considered by EDA tool as an algorithmic model failure. 

 

This suggests that two successive identical values should be an error and
cause simulation failure.

 

But later, the following text appears:

 

In the case of a receiver without a CDR, it is possible for only -1 to
ever be output during all AMI_GetWave calls.

 

This suggests that the EDA tool should *not* flag an error if successive
identical clock_times values are seen, so long as they are -1.   Without a
separate flag for "no_CDR", the tool has no insight into whether a CDR is
actually present or not.

 

Am I interpreting this correctly?

 

-          MM