That is exactly what I did, read the chart off line and then connected the DTp20 to computer and tried to read it with chartread. Was I using the correct syntax for chartread to do that ?

(using chartread -v -D  ./chart_name).

I am wondering though if the problem might also be that the DTP20 doesn't remotely read the chart but is limited to those produced by x-rite? I confess to knowing almost nothing about these devices but the instructions do say that after it has finished reading a chart it pulses steadily. This doesn't happen with this one, it just reads each row at a time giving a happy little beep at the end of each row and a 'ready' light but it doesn't seem to treat the last row any differently to the others.

Graeme Gill wrote:
Rob Smith wrote:
Trying again to read the DTP20 v1.02 chart, this time with 1.1.0rc2. Errors as follows:

dtp20: Sending '00030DS^M'response '<11>^M' ICOM err 0x11

You can't read strips interactively with your firmware (it doesn't
have the commands to do it). You should be able to read the
chart off-line, and then read it into Argyll though (if my
fixes have worked).

Graeme Gill.