[amayausers] Re: Trace

  • From: "HK Acree" <hkacree@xxxxxxxxxxxx>
  • To: <amayausers@xxxxxxxxxxxxx>
  • Date: Wed, 31 May 2006 23:52:15 -0700

If the previous does not work, push the Emergency Stop, then reach up behind 
the needle case and find the z axis shaft (it is visible in a square cutout 
behind the needle case), you can rotate it with your hand to bring the 
needle back up. Then re-engage the Emergency Stop (twist it), you may get a 
"not at head up" warning, if so go to "maintenance/head timing" and give the 
machine a head up command.

Herb
----- Original Message ----- 
From: "Kesavan" <kesavan@xxxxxxxxxxxxxx>
To: <amayausers@xxxxxxxxxxxxx>
Sent: Wednesday, May 31, 2006 7:20 PM
Subject: [amayausers] Re: Trace


>I have got x Axis time out error.
>
> The needle is  down and the grabber is stuck behind the needle.
>
> They are both stuck together
>
> How do I free them.
>
> Anand
> ===========================================================
>
> The AmayaUsers Mailing List
> Website: http://www.amayausers.com
> Discussion Board: http://www.amayausers.com/boards
> Subscribe/Unsubscribe: http://www.amayausers.com/list
>
> =========================================================== 

=========================================================== 

The AmayaUsers Mailing List
Website: http://www.amayausers.com
Discussion Board: http://www.amayausers.com/boards
Subscribe/Unsubscribe: http://www.amayausers.com/list

=========================================================== 

Other related posts: