[THIN] Re: Strange Ticket behaviour

  • From: "Jeff Pitsch" <jepitsch@xxxxxxxxx>
  • To: thin@xxxxxxxxxxxxx
  • Date: Thu, 2 Mar 2006 10:58:23 -0500

CSG requires that once a connection is directored to it that connection must
stay (sticky sessions).  If that is not happening you will get errors such
as this.  Also, WI and CSG must have the SAME lists of STA's.  If WI hands
out a ticket and CSG doesn't know about the STA, you'll get errors such as
this as well.

Jeff


On 3/2/06, Ivo Pastyrik <plaka@xxxxxxxxxx> wrote:
>
>  Greetings to all gurus here,
>
> I'm facing strange problem with ticketing in my PS4.0 Enviroment (two
> servers in farm).
> Users are accessing published application via icons created by PN Agent (
> 9.150) and they sometime get Windows logon screen when they start
> published application.
> This problem also sometime happen when I run application from WI.
> What is strange for me is that when I start Desktop on T1 server(through
> WI) I am connected to server T2 and I get Windows Logon screen.
> Desktop T1 is published on T1 server only, of course.
> I can see following eror in application event log:
> ---------------
> Event Type: Warning
> Event Source: wsxica
> Event Category: None
> Event ID: 5
> Date:  1.3.2006
> Time:  16:37:08
> User:  N/A
> Computer: TS03
> Description:
> Citrix Ticket Logon attempted on invalid ticket
> --------------
> I supose that users are facing the same problem (they are conneted to
> other server than they have ticket).
>
> I have also other problem with CSG on one server and I don't know if it is
> related to this one.
> I have installed CSG on both servers in farm (T1, T2) for failover.
> STA on T1 points to T1 and everything is OK, Ican sucessfully connect via
> CSG on T1.
>
> But if STA on T2 points to T2, I am unable to connect through CSG on T2.
> If STA on T2 points to T1, everything is OK - but in this case if T1 will
> fail I will not be able to use CSG on T2 due to missing STA.
>
> Each server has two NICs and MS Network loadbalancing is implemented for
> automatic failover - one for ICA connections a a second one for NLB cluster.
>
>
> Does anybody know how to troubleshoot this problem or what to check ?
>
> I will appreciate any help or information.
>
> Thank you in advance.
>
>
> Regards,
>
> Ivo Pastyrik
>
>
>
>
>