Chris - is the RAID BIOS getting that configuration from the drives thus
accepting into BIOS?  If so, then it sounds like my plan will work as
well it worked for you. 


Ron

-----Original Message-----
From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx] On
Behalf Of Chris Buechler
Sent: Wednesday, July 06, 2005 11:01 AM
To: thin@xxxxxxxxxxxxx
Subject: [THIN] Re: OT - Rebuild Citrix on second set of drives w/o
destroying old

On 7/6/05, Ron Jameson <rjameson@xxxxxxxxxxxxx> wrote:
>  
> I was hoping to be able to build the citrix on this server by pulling 
> the drives out and putting in a pair of new drives Raid1.  Then, when 
> my allotted time is out (to let people work again), put the original 
> drives back in and they can get back to work.  I will continue to do 
> this pull drives in & out until testing is done and finally released 
> to production people.  My problem I just thought of in the near last 
> hour is that I think the Dell Raid bios config will not just let me
pull drives in & out easily
> w/o config changes or reinit (thus losing data).   

I've done similar before on Dell PERC cards, even between different
servers (with identical configurations).  When you swap drives, at the
RAID POST it'll prompt to to accept the new configuration, and it'll
move along just fine after that.  Never caused a problem for me at
least.

-Chris
********************************************************
This Weeks Sponsor: Lakeside Software
SysTrack is the easiest to use, most complete way to monitor system and
application performance. SysTrack combines comprehensive monitoring
capabilities with hardware/software inventory, change management,
user/web
auditing, and reporting to create a total management solution.   
Evaluation at: http://www.LakesideSoftware.com
**********************************************************
Now available BriForum-The Video!
http://www.brianmadden.com/store/pc/viewPrd.asp?idproduct=idaffiliate=
Useful Thin Client Computing Links are available at:
http://thin.net/links.cfm
ThinWiki community - Excellent SBC Search Capabilities!
http://www.thinwiki.com
***********************************************************
For Archives, to Unsubscribe, Subscribe or set Digest or Vacation mode
use the below link:
http://thin.net/citrixlist.cfm
********************************************************
This Weeks Sponsor: Lakeside Software
SysTrack is the easiest to use, most complete way to monitor system and
application performance. SysTrack combines comprehensive monitoring 
capabilities with hardware/software inventory, change management, user/web
auditing, and reporting to create a total management solution.
Evaluation at: http://www.LakesideSoftware.com
**********************************************************
Now available BriForum-The Video!
http://www.brianmadden.com/store/pc/viewPrd.asp?idproduct=1&idaffiliate=3
Useful Thin Client Computing Links are available at:
http://thin.net/links.cfm
ThinWiki community - Excellent SBC Search Capabilities!
http://www.thinwiki.com
***********************************************************
For Archives, to Unsubscribe, Subscribe or
set Digest or Vacation mode use the below link:
http://thin.net/citrixlist.cfm

Other related posts: