[THIN] Re: Datastore failover..

  • From: Biju Chacko <bijumon@xxxxxxxxxxxxxxxx>
  • To: thin@xxxxxxxxxxxxx
  • Date: Thu, 04 Aug 2005 00:01:44 +0530

MessageThanx Steve!
  ----- Original Message ----- 
  From: Steve Parr 
  To: 'thin@xxxxxxxxxxxxx' 
  Sent: Wednesday, August 03, 2005 11:25 PM
  Subject: [THIN] Re: Datastore failover..


  If you still have access to the data on the hd's of the failed server and you 
can get the MF20.mdb

  and run 'dsmaint config' may be able to make your secondary the datastore.

   

  -----Original Message-----
  From: Steve Parr [mailto:sparr@xxxxxxxxxxxxx] 
  Sent: Wednesday, August 03, 2005 1:45 PM
  To: 'thin@xxxxxxxxxxxxx'
  Subject: [THIN] Re: Datastore failover..

   

  You will only get about 96 hrs to run without datastore.

  What you should look at is moving the datastore to the Secondary.

  Command may be 'dsmaint config'.. others can verify.

  Also a registry entry called PSRequired if I remember that if set to 0

  allows a secondary to run without having to contact the datastore when 
starting up.

   

  -----Original Message-----
  From: Biju Chacko [mailto:bijumon@xxxxxxxxxxxxxxxx] 
  Sent: Wednesday, August 03, 2005 1:38 PM
  To: thin@xxxxxxxxxxxxx
  Subject: [THIN] Datastore failover..

   

  Hi!!

   

  The primary windows 2003 /MFXP FR3 server failed,will be offline for a month..

  Secondary dont have datastore (access)

  What is best way to keepconnections alive?

  chfarmor failover?

   

  Thanx,

  waiting for advice!!

   

   

  Biju

   



------------------------------------------------------------------------------


  Internal Virus Database is out-of-date.
  Checked by AVG Anti-Virus.
  Version: 7.0.308 / Virus Database: 266.11.0 - Release Date: 29/04/2005

Other related posts: