[THIN] Re: Connection problem

  • From: "Gardiner, Jeffrey (MED US)" <jeffrey.gardiner@xxxxxxxxxxx>
  • To: <thin@xxxxxxxxxxxxx>
  • Date: Tue, 8 Apr 2008 12:46:04 -0400

Bill,
 
This reminds me of a problem where the ICA port was "accidentally"
changed from 1494 to 443 (so they could get through a firewall).  Also,
a firewall blocking TCP 1494 causes this error (unless you're using CSG
or another gateway).
 
Do you get the ICA sounder when you telnet to the server on port 1494?
 
Jeff

________________________________

From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx] On
Behalf Of Beckett, William (Bill)
Sent: Tuesday, April 08, 2008 11:02 AM
To: thin@xxxxxxxxxxxxx
Subject: [THIN] Connection problem


Ok list, since I seem to have Citrix support stumped at the moment, I'm
throwing this out here. I think most of you know more about it anyway. 
 
We've got a farm of ten. Datastore in corporate, I'm in a remote
location with 3 citrix servers on site. PS 4.0 on W2K3. 
 
We had beaucoup problem with the IMA service taking forever to start. An
issue within itself but right now it is started. However, no clients can
connect to two of the servers, either published applications OR desktop.
Client versions of all levels have been tried with no success. All
current rollups are applied. One server works so we are limping by on it
and I dare not reboot it. Very odd part of this...on the two servers
that are giving the following message - "Cannot connect to the
presentation server. There is no Citrix presentation server configured
on the specfied address", no clients can connect to them BUT they can
connect to each other. 
 
I've looked through the citrix site for the error above but nothing has
worked so far. I'm about to return another call to Citrix after trying
additional suggestions of theirs which haven't worked. Any thoughts or
ideas would be appreciated.
 


----------------------------------------------------------------------------
This message and any included attachments are from Siemens Medical Solutions 
and are intended only for the addressee(s). 
The information contained herein may include trade secrets or privileged or 
otherwise confidential information. Unauthorized review, forwarding, printing, 
copying, distributing, or using such information is strictly prohibited and may 
be unlawful. If you received this message in error, or have reason to believe 
you are not authorized to receive it, please promptly delete this message and 
notify the sender by e-mail with a copy to Central.SecurityOffice@xxxxxxxxxxx 

Thank you

Other related posts: