Sounds like your micro is dead, if this unit is NOT, I repeat NOT a hotel unit.... Damon Brunger damon101@xxxxxxxxxxxxxx Telrad Electronic Services Ft Wayne, IN 46815 ----- Original Message ----- From: "Comune Marino" <ragmandati@xxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Thursday, November 15, 2001 9:56 AM Subject: [TechAssist] tvc philips chassis gr2.2 > > Hi friends. > I've got a tvcset Philips gr2.2 chassis with the > following > fault: > -volume blocked, vol+ vol- buttons and rem.cont. > volume inoperative. > -I thought a hotel mode set,but > doesn't seeem to work (ch.38 etc) > -I noticed also that the vol. bar doesn't appear on > the screen on request. > -the micro is faultess along with the eeprom. > -if I drive pin 2 of the micro (in charge of the > volume)with an external variable supply the volume > beheaves normal. > Any suggestion. > Many thanks to you all for the attention. > > ALBERTO > > > ______________________________________________________________________ > > Abbonati a Yahoo! ADSL con Atlanet! > Naviga su Internet ad alta velocità, e senza limiti di tempo! > Per saperne di più vai alla pagina http://adsl.yahoo.it > ***************************************** > Help make your TechAssist online repair tips > database better! Submit your fixes here: > http://www.circuitwork.com/techassist/tip/#tips > ***************************************** > To UNSUBSCRIBE write to: > techassist-request@xxxxxxxxxxxxx > with unsubscribe in the subject line. > ***************************************** Help make your TechAssist online repair tips database better! Submit your fixes here: http://www.circuitwork.com/techassist/tip/#tips ***************************************** To UNSUBSCRIBE write to: techassist-request@xxxxxxxxxxxxx with unsubscribe in the subject line.