Last Update 5/8/2002 Event ID E08914321 Model KV27S22 Subject NO SYNC, RESET AFC DATA IN SERVICE MODE SYMPTOMS: No sync. Replaced the jungle IC, micro, AV switching IC, & tuner to no avail. RESOLUTION: Reset AFC data in service mode. Thank you for this valuable information. It will save the company and repair time for the customer. Bob Waterman, CET® #RI-28 Master Technician License #9109 Service Manager Gemini Computer, TV, & Security Alarms (508)695-7302 (508)695-7769 FAX geminitv@xxxxxxxxxxxxxxxx geminitv@xxxxxxx ----- Original Message ----- From: <electronicrepair@xxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Tuesday, January 21, 2003 5:47 PM Subject: [TechAssist] sony KV-27S22 > Set came in with the picture rolling from left to right, checked some of > the capacitors and the power supply, the seem to be OK, I have no print and > I have never seen this problem on a Sony. > Any help will be a big help. > > Thank you, > Electronic Repair Services > 48 W. James St. > Lancaster, PA 17603 > > > ------------------------------------------ > Submit A Repair Tip For Everyone Here: > http://www.tech-assist.org/secure/tip/main.html > ------------------------------------------ > To REMOVE your email address, click here: > http://www.tech-assist.org/unsubb.html > To CHANGE your email address, click here: > http://www.techassist.net/forms/change.html > > ------------------------------------------ Submit A Repair Tip For Everyone Here: http://www.tech-assist.org/secure/tip/main.html ------------------------------------------ To REMOVE your email address, click here: http://www.tech-assist.org/unsubb.html To CHANGE your email address, click here: http://www.techassist.net/forms/change.html