[TechAssist] ctc 187 wont start after xray protect test.

  • From: larry <schntv@xxxxxxxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Sat, 05 Jun 2004 10:42:24 -0400

well, i found the problem!
this is a first for me.
the degaussing coil was plugged on to the 2 testpoints in 
error, but removed and corrected.
same pin shape.
but this should not have permanently damaged the set.
the degauss coil should have worked just like the intentional 
short, that is recommended.
but, static charge from the coil zapped the xray protect 
transistor connected to the test point.
i guess i learn something every now and then.
Larry


-- 
Schneider TV & Electronic Inc.
5415 N. Wooster ave.
Dover, Ohio 44622       www.geocities.com/schntv2000/
330-343-0768         FCC. first class & Extra class K8WLY


-----------------------------------------------------------------------------
Lost Password:
http://www.tech-assist.org  and select "Login Problems?".
Email Archives:
//www.freelists.org/archives/techassist/

Other related posts:

  • » [TechAssist] ctc 187 wont start after xray protect test.