Unit came in with HOT shorted, found IHVT with a pin hole in it arcing to the metal shield for the AC plug. I repaired the hole to verify nothing else was wrong with the unit before ordering a flyback. Unit ran for a few minutes. Order FBT from Tritronics #232191 which is a new part. After installing new part, unit would not turn on for a few seconds, then R762 on power board started to smoke...or at least smoke came from this direction. I quickly turned of the variac. I replaced the FBT I had repaired, and now unit only clicks numerous times after pressing power, press power again and stops clicking. R762U reads about 1.2K, but color code appears to be yellow, black and third band is burnt. I have no print. So, either I got a bad flyback or this was not the right part number? Any suggestions? Jeff FAX 717-564-4952 Jeff Dougherty Intrepid Video & Electronics Be careful of your thoughts. 501 Luther Rd They may become your words Harrisburg, PA 17111 any moment. 717-909-8844 VCR tips, electronics info & general interest. www.intrepid-video.com www.tech-repair.net www.thetoolcaddy.com www.9-11-2001tragedy.com *********************************************************************** ------------------------------------------ To REMOVE your email address, click here: http://www.tech-assist.org/unsubb.html To CHANGE your email address, click here: http://www.techassist.net/forms/change.html ------------------------------------------ ***NEW*** Tips Added Instantly!!!*** Submit Repair Tips here: http://www.tech-assist.org/secure/tip/