These H.V diodes on the main capacitor test real high on a meter , probably OK. They usually short not open up. Test all the switches inside at door latch. Just remove wires to each one and run a continuity check on each. The door safety switch will cause fuse to blow. You can put a 100 watt bulb in place of the 15 amp fuse instead of using up fuses. Test the magnetron first by testing for continuity from input leads to magnetron case should show open. If it test shorted then it is the megaton causing the problem. Bruce. B&T Electronics 139 Margaret St Sarnia Ontario Canada N7T 2Y3 519 344 1850 ----- Original Message ----- From: "Intrepid Video Support" <support@xxxxxxxxxxxxxxxxxx> To: "Techassist" <techassist@xxxxxxxxxxxxx> Sent: Tuesday, June 01, 2004 12:18 PM Subject: [TechAssist] TA Microwave GE JE1390 > > > I do very few microwaves, but I hoped this would be simple... > Found 15A fuse open. > Replaced and unit would run for about 5 seconds, but I don't think it started to heat at all and fuse > blew. > Found diode HVR-1X from main cap to ground open. (Also has SK6918 on it). Measures open on diode test > anyway. > Can someone guide me to what else I may need to look for on this? I've seen posts about switches blowing > fuses, but don't know how to test them on this. > Thank you. > > Jeff > -- > Intrepid Video TV/VCR Repair > 263 S Front St, Steelton PA 17113 > 717-939-7708; (F) 717-564-4952 > www.intrepid-video.com www.tech-repair.net > > > -------------------------------------------------------------------------- --- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/