On the 1390 the upper door switch is meant to blow fuse and uses both the NO and NC function.Bottom switch only uses NO conn. which closes as door is shut,If you have to replace these switches,be sure to figure in modifying the plunger[easy] as it doesn't stick out enough on the replacements[crazy glue] To isolate the maggie as to cause,I pull the HiV lead off it and energize the cook fcn, That oil-filled cap will really knock you silly,so discharge it or stay away from it,Let me know.Regards, Pete Intrepid Video Support <support@xxxxxxxxxxxxxxxxxx> wrote: I do very few microwaves, but I hoped this would be simple... Found 15A fuse open. Replaced and unit would run for about 5 seconds, but I don't think it started to heat at all and fuse blew. Found diode HVR-1X from main cap to ground open. (Also has SK6918 on it). Measures open on diode test anyway. Can someone guide me to what else I may need to look for on this? I've seen posts about switches blowing fuses, but don't know how to test them on this. Thank you. Jeff -- Intrepid Video TV/VCR Repair 263 S Front St, Steelton PA 17113 717-939-7708; (F) 717-564-4952 www.intrepid-video.com www.tech-repair.net ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/ Peter Neal Neal Electronics 1905 E. Wm.Cannon Austin,TX 78756 ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/