The power supply is complicated in that model and difficult to troubleshoot. I would hope to find an electrolytic with high ESR. Some of them are critical. Jerry Silverman Greentron Inc 4 Newland Ave Greenville SC 29609 864 232 3889 Fax 271 2080 mailto:greentron@xxxxxxx ----- Original Message ----- From: "Bruce Youmans" <youmans@xxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Tuesday, January 08, 2002 2:46 PM Subject: [TechAssist] Re: Sony SL-2500 Beta Dead, Part ID > > Jerry, > > There is no 12 volts on the input. Because I'm working without a schematic > I'm not sure there is 12 volts on the input when the VCR is in the standby > (off) mode. Yes, it is possible an electrolytic capacitor or two may be bad > because of the age.. I have checked most of them and so far the ESR is good. > I was also thinking that there may be a ICP or low value resistor that has > opened. This is because everything is inoperative, even the clock in the off > mode. The customer said the VCR was plugged in and one day when they went to > use it everything was dead. I have checked all three of the fuses and they > are OK. There are some voltages on the power supply board in various > locations. Not sure if they are correct. Any other thoughts you might have > are appreciated. > > Bruce > ----- Original Message ----- > From: J Silverman <greentron@xxxxxxxxxxxxxxxx> > To: <techassist@xxxxxxxxxxxxx> > Sent: Tuesday, January 08, 2002 10:45 AM > Subject: [TechAssist] Re: Sony SL-2500 Beta Dead, Part ID > > > > > > If that IC has 12 volts input, it should have 9 volts output. If there is > no > > 12 volts the problem is elsewhere. I dont recall ever having a power > problem > > with that model. Considering the age, I would think some of the > electrolytic > > capacitors may be dried out. > > Jerry Silverman > > Greentron Inc > > 4 Newland Ave > > Greenville SC 29609 > > 864 232 3889 > > Fax 271 2080 > > mailto:greentron@xxxxxxx > > ----- Original Message ----- > > From: "Bruce Youmans" <youmans@xxxxxxxx> > > To: <techassist@xxxxxxxxxxxxx> > > Sent: Monday, January 07, 2002 12:50 PM > > Subject: [TechAssist] Re: Sony SL-2500 Beta Dead, Part ID > > > > > > > > > > Thanks Jerry. > > > > > > I have been trying to repair this VCR without a schematic. The part had > no > > > information on it. I was hoping that this part would be the reason the > VCR > > > is dead, has no display, and no function operation at all. > > > > > > Bruce > > > Bruce's TV Service > > > Sierra Vista, Arizona > > > > > > ----- Original Message ----- > > > From: J Silverman <greentron@xxxxxxxxxxxxxxxx> > > > To: <techassist@xxxxxxxxxxxxx> > > > Sent: Monday, January 07, 2002 9:58 AM > > > Subject: [TechAssist] Re: Sony SL-2500 Beta Dead, Part ID > > > > > > > > > > > > > > That is a 78M08, standard 8 volt, 1/2 amp 3 terminal voltage > regulator. > > > Sony > > > > 8 759 170 08. > > > > Jerry Silverman > > > > Greentron Inc > > > > 4 Newland Ave > > > > Greenville SC 29609 > > > > 864 232 3889 > > > > Fax 271 2080 > > > > mailto:greentron@xxxxxxx > > > > ----- Original Message ----- > > > > From: "Bruce Youmans" <youmans@xxxxxxxx> > > > > To: <techassist@xxxxxxxxxxxxx> > > > > Sent: Sunday, January 06, 2002 10:57 PM > > > > Subject: [TechAssist] Re: Sony SL-2500 Beta Dead, Part ID > > > > > > > > > > > > > > > > > > Need to know the part number for IC3 on the power supply board. > > > > > This unit is a Sony Sl-2500, but is similar to a Zenith VR-9775. > > > > > > > > > > Thanks. > > > > > > > > > > Bruce > > > > > Bruce's TV Service > > > > > Sierra Vista, Arizona > > > > > > > > > > ----- Original Message ----- > > > > > From: Bruce Youmans <youmans@xxxxxxxx> > > > > > To: <techassist@xxxxxxxxxxxxx> > > > > > Sent: Friday, January 04, 2002 9:36 AM > > > > > Subject: [TechAssist] Re: Sony SL-2500 Beta Dead > > > > > > > > > > > > > > > > > > > > > > Just learned this Sony Beta is similar to a Zenith VR9775 in case > > > anyone > > > > > has > > > > > > information on either. > > > > > > > > > > > > Thanks > > > > > > > > > > > > Bruce > > > > > > Bruce's TV Service > > > > > > Sierra Vista, Arizona > > > > > > > > > > > > ----- Original Message ----- > > > > > > From: Bruce Youmans <youmans@xxxxxxxx> > > > > > > To: <techassist@xxxxxxxxxxxxx> > > > > > > Sent: Wednesday, January 02, 2002 10:18 PM > > > > > > Subject: [TechAssist] Sony SL-2500 Beta Dead > > > > > > > > > > > > > > > > > > > Manufacturer: Sony > > > > > > > Model: SL-2500 Beta VCR > > > > > > > Symptom: Dead > > > > > > > > > > > > > > Received today a Sony Beta VCR for repair. Not sure this is > worth > > > > > digging > > > > > > into unless it may be something simple. Unit is totally dead. No > > > display > > > > > or > > > > > > any action when the power button is pushed. Primary fuse, F1, is > > fine. > > > > No > > > > > > schematic on this one and the unit is pretty compact so I hate to > > dig > > > > into > > > > > > it without some advance help. Any help would be appreciated. > > > > > > > > > > > > > > Bruce > > > > > > > Bruce's TV Service > > > > > > > Sierra Vista, Arizona > > > > > > > > > > > > > > ------------------------------------------ > > > > > > > Help make your TechAssist database better! > > > > > > > Submit your fixes here: > > http://circuitwork.com/techassist/tip/#tips > > > > > > > ------------------------------------------ > > > > > > > To UNSUBSCRIBE your email address, click here: > > > > > > > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > > > > > > > Or send a BLANK email with unsubscribe in the > > > > > > > SUBJECT field to the address above. > > > > > > > > > > > > > > > > > > > > > > > > > > ------------------------------------------ > > > > > > Help make your TechAssist database better! > > > > > > Submit your fixes here: > http://circuitwork.com/techassist/tip/#tips > > > > > > ------------------------------------------ > > > > > > To UNSUBSCRIBE your email address, click here: > > > > > > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > > > > > > Or send a BLANK email with unsubscribe in the > > > > > > SUBJECT field to the address above. > > > > > > > > > > > > > > > > > > > > > > ------------------------------------------ > > > > > Help make your TechAssist database better! > > > > > Submit your fixes here: http://circuitwork.com/techassist/tip/#tips > > > > > ------------------------------------------ > > > > > To UNSUBSCRIBE your email address, click here: > > > > > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > > > > > Or send a BLANK email with unsubscribe in the > > > > > SUBJECT field to the address above. > > > > > > > > > > > > > ------------------------------------------ > > > > Help make your TechAssist database better! > > > > Submit your fixes here: http://circuitwork.com/techassist/tip/#tips > > > > ------------------------------------------ > > > > To UNSUBSCRIBE your email address, click here: > > > > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > > > > Or send a BLANK email with unsubscribe in the > > > > SUBJECT field to the address above. > > > > > > > > > > > > > > ------------------------------------------ > > > Help make your TechAssist database better! > > > Submit your fixes here: http://circuitwork.com/techassist/tip/#tips > > > ------------------------------------------ > > > To UNSUBSCRIBE your email address, click here: > > > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > > > Or send a BLANK email with unsubscribe in the > > > SUBJECT field to the address above. > > > > > > > > > > ------------------------------------------ > > Help make your TechAssist database better! > > Submit your fixes here: http://circuitwork.com/techassist/tip/#tips > > ------------------------------------------ > > To UNSUBSCRIBE your email address, click here: > > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > > Or send a BLANK email with unsubscribe in the > > SUBJECT field to the address above. > > > > > > ------------------------------------------ > Help make your TechAssist database better! > Submit your fixes here: http://circuitwork.com/techassist/tip/#tips > ------------------------------------------ > To UNSUBSCRIBE your email address, click here: > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > Or send a BLANK email with unsubscribe in the > SUBJECT field to the address above. > ------------------------------------------ Help make your TechAssist database better! Submit your fixes here: http://circuitwork.com/techassist/tip/#tips ------------------------------------------ To UNSUBSCRIBE your email address, click here: mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe Or send a BLANK email with unsubscribe in the SUBJECT field to the address above.