You have yourself a bad flyback (NX-4600//X4J4) and that is Sony part # 1-453-338-11. Bob Waterman, CET® #RI-28 Master Technician License #9109 Service Manager / Parts Manager Gemini Computer, TV, & Security Alarms (508)695-7302 (508)695-7769 FAX geminitv@xxxxxxxxxxx ----- Original Message ----- From: "Bob@Bobs tv" <woodman1@xxxxxxxx> To: "TechAsist M" <techassist@xxxxxxxxxxxxx> Sent: Thursday, October 14, 2004 12:33 PM Subject: [TechAssist] Sony KV32FS13 Dead > KV32FS13 > SCC-S40--QA > This set appears to have a over current problem, when the power is turned on set comes on then clicks off with two blinks.. When turning on, the B+ changes so fast you can not read on meter...Monitoring the HV at turn on, the HV does not try to come up. Unhooking HOT the B+ goes to 135V for aprox 5 seconds then shuts down again.. Did a visual check along with static check of semis, but that is as far as I gone.. Would appreciate any help on how to proceed, as this is a new set to me... > Using a KV32FS12 manual... > > Thank You > > Bob, > > Bobs TV Worcester, ma > > woodman1@xxxxxxxx > > Main 508-853-1482 > Fax 508-853-1480 > > -------------------------------------------------------------------------- --- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/