Make : Sony
Model : KV27FS13  New ...right out of the box  ( 27" WEGA/VEGA)
Problem : Shutting down on startup.  LED code blinks 2 times.

Scoping the Horiz Output collectors waveform , we saw excessive ringing &
static between H pulses.  Figured the flyback was the issue.  Changed
it.....no help.

A little more digging revealed D504 shorted ( ERC06-15) ....this is
paralleled across an identical diode D501.

Replaced the diode ( From a scrap set).....set fired up HV great......then
shutdown a few seconds later.  Now 4 blinks!  ( Vert failure)

Scoping the yoke pins...showed very little/weak drive.  Changed the TDA8172
...used the STV sub for that.

Still no fix....cycled the set a dozen or so times while checking waveforms
the D504 shorted again !!  UHG !

Odd for this set to be like this right out of the box.     This set was
bought at a local casino with comp points....customer doesn't want to go
thru the warranty routes...he's willing to pay us to do it.

Is there any Sony bulletins on this model OR a PDF file someone could send
us for this newer set?


Jeff Stielau
Shoreline Electronics Repair
125 Beech Tree Lane
Westbrook, CT 06498
860-399-1861
860-664-3535 (fax)
jstielau@xxxxxxxx


------------------------------------------
To REMOVE your email address, click here:
  http://www.tech-assist.org/unsubb.html
To CHANGE your email address, click here:
  http://www.techassist.net/forms/change.html
------------------------------------------
***NEW*** Tips Added Instantly!!!***
Submit Repair Tips here: 
http://www.tech-assist.org/secure/tip/

Other related posts: