Set came in with a complaint of No Power and 'flash' behind the right speaker at Power on. I get immediate shutdown at plug-in.I think the Flash is a relay closing but not sure. Anyway,I disconnected the flyback input to the HV Splitter and the set fired up at plug-in. I put the flyback anode back in to test the Picture tubes one at a time,but before I disconnected any of the Tube anodes from the HV splitter,I plugged it back up.Set came on momentarily then died.Now I don't even get shutdown,it's dead. Found on the 'N' board Q811 2sd1887 shorted,andQ801 2sd2555 shorted. also on the 'G' board found Q603 and Q614,both 2sc4582, shorted and R604 .1 ohm open. Tritronics has HV Tripler as 1-453-108-11,replaced by -12, $140.94 retail. Has anyone been down this road,or have some tips on this set. It belongs to a good friend Peggs Peggs' Electronics 1519 West 2nd Street Owensboro,KY 42301 270-926-4968 fax 270-686-7399 peggs@xxxxxxxxxxxxx ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/