[TechAssist] Sony CVM-1270 SCC469 going into shutdown

  • From: "Peter oliver" <oliver_peter1@xxxxxxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Sun, 08 May 2005 15:48:19 +0000

Sony 12" commercial use only TV monitor from 1983
CVM-1270
SCC469A-A

               Set came in with a severe screeming power supply. 2 caps were 
bad on the upright SW mode supply. A 47uf and a 2.2uf changing them 
eliminated the screaming from the supply. Set will now run for a few min 
(3-5 min) then go to what appears to be high voltage shutdown ( I've tried 
removing the overvoltage shutdown lead from the HV static convergace block 
with out luck). Set usualy only starts on the second try (It was only 
starting with my meter across the 110 dc supply from the PS board (simulated 
the meter with a 1 meg). Also there is a resitor out to the sound first 2 
digits are 27 multiplier is out I was thinging it was r185 but don't have 
the set in front of me at the moment to verify. Don't have a schematic. Any 
ideas?

Peter Oliver
Tucson Radio TV


-----------------------------------------------------------------------------
This Email List is Public. Remove: http://www.tech-assist.org/remove.htm