[TechAssist] Re: Sharp 32U-S50 lightning damage

  • From: Al Gutz <alg@xxxxxxxxxxx>
  • To: techassist@xxxxxxxxxxxxx
  • Date: Wed, 13 Jul 2005 22:05:37 -0400

Charles

Load the PS with a 60 watt bulb till you find the trouble. Saves on HOTs

Al G

repair11 wrote:
> 
>  Sharp 32U-S50 came in dead after lightning, found hot shorted, rang fly ok,
> replaced hot after checking parts in reg ckt,fired set up, hot instantly
> shorted, wicked off collector ,B+was215v,ordered reg driver IC, replaced
> this chip, as well as  SE125 reg, and optocoupler, plugged set in, blew
> hot,B+ is still running 215v, a scan of ps or suggestions would be greatly
> appreciated. I see very few sharps.
> 
> 
>  Charles Betzler
>  Best Electronics
>  repair11@xxxxxxx
> 
> 
> 
> -----------------------------------------------------------------------------
> This Email List is Public. Remove: http://www.tech-assist.org/remove.htm
> Set Vacation mailto:ecartis@xxxxxxxxxxxxx?subject=set%20techassist%20vacation
> Lost Password: http://www.tech-assist.org  and select "Login Problems?".
> Email Archives: //www.freelists.org/archives/techassist/
> 

-----------------------------------------------------------------------------
This Email List is Public. Remove: http://www.tech-assist.org/remove.htm
Set Vacation mailto:ecartis@xxxxxxxxxxxxx?subject=set%20techassist%20vacation
Lost Password: http://www.tech-assist.org  and select "Login Problems?".
Email Archives: //www.freelists.org/archives/techassist/