Check the HOT as well as the solder on the horizontal drive transformer. The B+ may be a bit high at 154v. something is shorted though if it goes into shutdown immediately. Hope this gives you some direction. Frank Rs-Tek Inc. ----- Original Message ----- From: <tvdoctors@xxxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Friday, February 01, 2002 2:25 PM Subject: [TechAssist] Sharp 25R-M100 > No print on this unit. Replaced flyback transformer and regulator IC701, but still won't run. Tries to come up at first plug in but goes to immediate shutdown. Secondary power supply voltages are 154volts, 15 volts, and 11 volts. Can anyone shed some light on this one, Thanks, Neil > > TV Doctors 108 W. Main St. Monroe,Wa. 98272 360-794-6469 > > ------------------------------------------ > Make your TechAssist database better! > Submit Repair Tips here: http://www.tech-assist.org/secure/tip/ > ------------------------------------------ > To UNSUBSCRIBE your email address, click here: > mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe > Or send a BLANK email with unsubscribe in the > SUBJECT field to the address above. > > ------------------------------------------ Make your TechAssist database better! Submit Repair Tips here: http://www.tech-assist.org/secure/tip/ ------------------------------------------ To UNSUBSCRIBE your email address, click here: mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe Or send a BLANK email with unsubscribe in the SUBJECT field to the address above.